Primary Magnet Rundown Unit MRU2006
| 5196918-2 | |
| 5196918 2128700 46-252138G4 46-294231G1 | |
| Neuf | |
| Imagerie par résonance magnétique (IRM) | |
| GE Healthcare | |
| GE HealthCare | Exchange - Return Defective |
|
Core Exchange | |
Enter your approval number and submit to add item(s) to cart.
Please enter approval number
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.
Select your approver's name and submit to add item(s) to your cart
Please Select Approver Name
OR
Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.
If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.
Features
- MRU2006 available with instruction CD
- Made of high-quality material
- Enhanced durability
- Perfect fit and finish for the assembly
Fréquemment acheté avec cet article
Présentation du produit
The Primary Magnet Rundown Unit MRU2006 is a part used in Magnetic Resonance Imaging. This assembly consists of primary box, main PCB, main bottom PCB, battery pack, cable assembly for circuit breaker, cable assembly breaker, overlay, battery cover, warning label in ferrous material, green lens, red lens, light pipe, hardware-panel mounting, dress nut, cap for green, red and aluminum push buttons, hinge, hole-plug , stand-off and also having required nuts and washers. The run-down unit initiates a controlled quench and turns off the magnetic field. It is typically a big red button located on the wall of the magnet room near the door. It may be labelled ""Magnet Stop"" or ""Emergency Run Down"". This button should only be used in a life-threatening emergency, such as a patient pinned in the scanner by a metal object or a fire in the magnet gantry. Does not quench the magnet but turns off most electrical power in the scanner room and operator area, including the console, computers, patient table, and anything on the UPS (uninterrupted power supply) circuitry. It may be a simple red button sometimes labeled with the confusing wording ""Emergency Stop"" or a more sophisticated control unit as shown to the right. Emergency lighting is not affected and depending on system design and choices, there may be residual power to gradients and other devices in the equipment room. This switch should be used when there is a serious equipment fault or hazard, such as fire or water in the vicinity of the MR scanner.
Article(s) équivalent(s):
Below is more information on the equivalent item(s). Items without a hyperlink are listed for reference only and are not available for purchase online.
| Article(s) équivalent(s) | Nom du produit |
|---|---|
| 5196918 | 5196918 |
| 2128700 | |
| 46-252138G4 | ERU ASSY |
| 46-294231G1 | 46-294231G1 |
Return And Exchange
GE HealthCare will accept, for return from customer, items that are in new condition, unworn, unaltered and free of damage. Items cannot be returned or exchanged beyond 30 days from customer’s receipt of the original order and all returned items will be subject to a 15% restocking fee. To obtain a full refund or exchange of the item within the 30 day return period (subject to the 15% restocking fee) customer must request a return materials authorization (RMA) from GE HealthCare and return the item to GE HealthCare utilizing this RMA number. Items must be returned in the original packaging, unused and free of damage.